KOHLER.SDMO KD165 发电机组 发动机配件 132千瓦
柴油发电机/ KD165
KOHLER-SDMO电力产品系列的标准发电机组可提供7.5至4,200 kVA的所有电力需求。它们专为工业用户设计,涵盖广泛的应用领域,提供广泛的选项和改造,以完全满足所有配置的要求。
通过安全的工程工具门户构建您的能源解决方案。使用尺寸调整程序功能,通过Spec Editor生成技术规格,并从产品目录中查看有关KOHLER-SDMO工业发电机组的详细信息。
主要评级: |  | 120千瓦(150千伏安) |
|
待机评级: |  | 132千瓦(165千伏安) |
|
赫兹: |  | 50赫兹 |
|
交流发电机类型: |  | 4极,旋转场 |
|
引擎制造商: |  | 约翰迪尔 |
|
发动机型号: |  | 6068HF120-153 |
|
气缸布置: |  | 6内联 |
|
额定转速下的最大功率: |  | 153千瓦(205 BHP) |
|
优质燃油消耗量 |  |
|
100%负载: |  | 33.5 Lph(8.9加仑) |
75%负载: |  | 25 Lph(6.6加仑) |
50%负载: |  | 17 Lph(4.5加仑) |
|
KD165
Engine type
Alternator type
Performance class
6068HF120-153
KH01340T
G3
GENERAL CHARACTERISTICS
Frequency (Hz)
Voltage (V)
Standard control panel
Optional control panel
Optional control panel
POWER
ESP PRP
Voltage
kWe kVA kWe kVA
Standby Amps
200/115 132 165 120 150 476
240 TRI 132 165 120 150 397
230 TRI 132 165 120 150 414
220 TRI 132 165 120 150 433
220/127 119 149 108 135 391
DIMENSIONS COMPACT VERSION
Length (mm) 2370
Width (mm) 1114
Height (mm) 1480
Dry weight (kg) 1578
Tank capacity (L) 340
DIMENSIONS SOUNDPROOFED VERSION
Commercial reference of the enclosure M226
3508
1200
1830
2168
340
75
Length (mm)
Width (mm)
Height (mm)
Dry weight (kg)
Tank capacity (L)
Acoustic pressure level @1m in dB(A)
Sound power level guaranteed (Lwa)
Acoustic pressure level @7m in dB(A)
94
POWER DEFINITION
PRP : Prime Power is available for an unlimited number of annual
operating hours in variable load applications, in accordance with ISO
8528-1. ESP : The standby power rating is applicable for supplying
emergency power in variable load applications in accordance with ISO
8528-1. Overload is not allowed
TERMS OF USE
According to the standard, the nominal power assigned by the genset is
given for 25°C Air Intlet Temperature, of a barometric pressure of 100
kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions
in your installation, refer to the derating table.
ASSOCIATED UNCERTAINTY
For the generator sets used indoor, where the acoustic pressure levels
depend on the installation conditions, it is not possible to specify the
ambient noise level in the operating and maintenance instructions.
You will also find in our operating and maintenance instructions a
warning concerning the air noise dangers and the need to implement
appropriate preventive measures.
50
400/230
APM303
DEC4000
M80
DESCRIPTIVE
Kohler Co. Provides one-source responsibility for the
generating system and accessories
The generator set and its components are prototypetested,
factory-built, and production-tested
A one-year limited warranty covers all systems and
components
Mechanic governor
Mechanically welded chassis with antivibration
suspension
Main line circuit breaker
Radiator for core temperature of 48/50°C max with
mechanical fan
Protective grille for fan and rotating parts (CE option)
9 dB(A) silencer supplied separately
Charger DC starting battery with electrolyte
12 V charge alternator and starter
Delivered with oil and coolant -30°C
Manual for use and installation
64
415/240 132 165 120 150 230
400/230 132 165 120 150 238
380/220 132 165 120 150 251
KD165
ENGINE CHARACTERISTICS
JOHN DEERE
6068HF120-153
Turbo
6
6.72
Air/Air DC
106 x 127
17 : 1
1500
6.35
153
+/- 2.5%
16.60
GENERAL ENGINE DATA
Engine model
Engine type
Air inlet
Cylinders arrangement
Number of cylinders
Displacement (L)
Charge Air coolant
Bore (mm) x Stroke (mm)
Compression ratio
Speed (RPM)
Pistons speed (m/s)
Maximum stand-by power at rated
RPM (kW)
Frequency regulation, steady state (%)
BMEP (bar)
Governor type Mechanical
COOLING SYSTEM
Radiator & Engine capacity (L) 25.8
Max water temperature (°C) -
Outlet water temperature (°C) -
Fan power (kW) 3
Fan air flow w/o restriction (m3/s) 4.44
Available restriction on air flow (mm
H2O)
Type of coolant
Thermostat modulating range HT (°C)
20
Glycol-Ethylene
-
80
150
-
EMISSIONS
Emission PM (mg/Nm3) 5% O2
Emission CO (mg/Nm3) 5% O2
Emission HC+NOx (g/kWh)
Emission HC (mg/Nm3) 5% O2 35
555
385
EXHAUST
Exhaust gas temperature @ ESP 50 Hz (°C)
Exhaust gas flow @ ESP 50Hz (L/s)
Max. exhaust back pressure (mm H2O) 750
FUEL
Consumption @ 110% load (L/h) 36.5
Consumption @ 100% load (L/h) 33.5
Consumption @ 75% load (L/h) 25
Consumption @ 50% load (L/h) 17
Maximum fuel pump flow (L/h) 108
21.5
1
5
-
OIL
Oil capacity (L)
Min. oil pressure (bar)
Max. oil pressure (bar)
Oil consumption 100% load (L/h)
Oil sump capacity (L) 20.6
99
16
HEAT BALANCE
Heat rejection to exhaust (kW)
Radiated heat to ambient (kW)
Heat rejection to coolant (kW) 55
625
AIR INTAKE
Max. intake restriction (mm H2O)
Intake air flow (L/s) 170
L
KD165
ALTERNATOR CHARACTERISTICS
GENERAL DATA
Alternator type KH01340T
Number of Phase Three phase
Power factor (Cos Phi) 0.8
Altitude (m) 0 to 1000
Overspeed (rpm) 2250
Number of pole 4
Capacity for maintaining short circuit at
3 ln for 10 s No
Insulation class H
T° class(H/125°), continuous 40°C H / 125°K
T° class, standby 27°C H / 163°K
AVR Regulation Yes
Total Harmonic Distortion in no-load
DHT (%) <2
Total Harmonic Distortion, on load DHT
(%) <5
Wave form : NEMA=TIF <50
Wave form : CEI=FHT <2
Number of bearing 1
Coupling Direct
0.5
500
Voltage regulation at established rating
(+/- %)
Recovery time (Delta U = 20%
transient) (ms)
Protection class IP 23
Technology Without collar or
brush
OTHER DATA
Continuous Nominal Rating 40°C (kVA) 150
Standby Rating 27°C (kVA) 165
Efficiencies 100% of load (%) 92.9
Air flow (m3/s) 0.25
Short circuit ratio (Kcc) 0.487
Direct axis synchro reactance unsaturated (Xd) (%) 305
Quadrature-axis synchro reactance unsaturated (Xq)
(%)
Open circuit time constant (T'do) (ms) 2077
14.6
100
8.8
10
17.4
10
Direct axis transient reactance saturated (X''d) (%)
Short circuit transient time constant (T'd) (ms)
Direct axis subtransient reactance saturated (X''d) (%)
Subtransient time constant (T""d) (ms)
Quadrature-axis subtransient reactance saturated
(X"q) (%)
Subtransient time constant (T"q) (ms)
Zero sequence reactance unsaturated (Xo) (%) 0.6
Negative sequence reactance saturated (X2) (%) 13.11
Armature time constant (Ta) (ms) 15
No load excitation current (io) (A) 0.67
Full load excitation current (ic) (A) 2.45
29.9
324.07
Full load excitation voltage (uc) (V)
Engine start (Delta U = 20% perm. or 50% trans.)
(kVA)
Transient dip (4/4 load) - PF : 0,8 AR (%) 13
No load losses (W) 2861.03
Heat rejection (W) 9127.9
DIMENSIONS
M226
3508
1200
1830
2168
340
75
Dimensions soundproofed version
Commercial reference of the enclosure
Length (mm)
Width (mm)
Height (mm)
Dry weight (kg)
Tank capacity (L)
Acoustic pressure level @1m in dB(A)
Sound power level guaranteed (Lwa)
Acoustic pressure level @7m in dB(A)
94
Dimensions DW compact version
Commercial reference of the enclosure -
3560
1180
1822
1981
868
-
Length (mm)
Width (mm)
Height (mm)
Dry weight (kg)
Tank capacity (L)
Acoustic pressure level @1m in dB(A)
Sound power level guaranteed (Lwa)
Acoustic pressure level @7m in dB(A)
-
155
Unbalanced load acceptance ratio (%) 100
64 -
M226 DW
3560
1200
2182
2561
868
74
Dimensions DW soundproofed version
Commercial reference of the enclosure
Length (mm)
Width (mm)
Height (mm)
Dry weight (kg)
Tank capacity (L)
Acoustic pressure level @1m in dB(A)
Sound power level guaranteed (Lwa)
Acoustic pressure level @7m in dB(A)
94
Dimensions DW 48h soundproofed version
M226 DW48
3560
1200
2364
2816
1630
74
Commercial reference of the enclosure
Length (mm)
Width (mm)
Height (mm)
Dry weight (kg)
Tank capacity (L)
Acoustic pressure level @1m in dB(A)
Sound power level guaranteed (Lwa)
Acoustic pressure level @7m in dB(A)
94
64 64
KD165
CONTROL PANEL
DEC4000, ergonomic and user-friendly
APM303, comprehensive and simple
The APM303 is a versatile unit which can be operated in
manual or automatic mode. It offers the following features:
Measurements:
phase-to-neutral and phase-to-phase voltages, fuel level
(In option : active power currents, effective power, power
factors, Kw/h energy meter, oil pressure and coolant
temperature levels)
Supervision:
Modbus RTU communication on RS485
Reports:
(In option : 2 configurable reports)
Safety features:
Overspeed, oil pressure,coolant temperatures, minimum
and maximum voltage, minimum and maximum frequency
(Maximum active power P<66kVA)
Traceability:
Stack of 12 stored events
For further information, please refer to the data sheet for the
APM303.
The highly versatile DEC4000 control unit is complex
yet accessible, thanks to the particular attention paid to
optimising its ergonomics and ease of use. With its large
display screen, buttons and scroll wheel, it places the
accent on simplicity and communication.
The DEC4000 offers the following functions:
Electrical measurements: voltmeter, frequency meter,
ammeter.
Engine parameters: working hours counter, oil pressure,
coolant temperature, fuel level, engine speed, battery
voltage.
Alarms and faults: oil pressure, coolant temperature, failure
to start, overspeed, alternator min./max., battery voltage
min./max., emergency stop, fuel level.
Ergonomics: wheel for navigating around the various
menus.
Communication: remote control and operation software,
USB connections, PC connection.
For more information on the product and its options, please
refer to the sales documentation.
KD165
CONTROL PANEL
Basic terminal block
The control unit can be used as a basic terminal block for
connecting a control box.
Offers the following functions:
emergency stop button, customer connection terminal
block, CE.
M80, transfer of information
The M80 is a dual-function control unit. It can be used as a
basic terminal block for connecting a control box and as an
instrument panel with a direct read facility, with displays
giving a global view of your generating set's basic
parameters.
Offers the following functions:
Engine parameters: tachometer, working hours counter,
coolant temperature indicator, oil pressure indicator,
emergency stop button, customer connection terminal
block, CE.